Skip to content

Constructions

Constructions and glazings of the examples

FastSmoothBuildings.Examples.Constructions, package (source)

Extends FastSmoothBuildings.Icons.Package.

Class Description
LightWall Light wall of BESTEST case 600: wood siding, fiberglass, plasterboard
LightRoof Light roof of BESTEST case 600: roof deck, fiberglass, plasterboard
LightFloor Light floor of BESTEST case 600: insulation over outdoor air, timber flooring
DoubleClear Clear double glazing of BESTEST case 600: two 3 mm panes, 12 mm of air
CavityWall Insulated cavity wall: brick, insulation, block, plaster; the layers split into sublayers
ConcreteSlab Concrete slab of 25 cm in two layers of two sublayers
TripleArgon Triple glazing with argon and two low-emissivity coatings

The constructions of BESTEST case 600 (ASHRAE Standard 140) and of trano's single-zone hydronic test, written as trano writes them: the counts of sublayers and the indices of the nodes are literal (see Translation into CasADi).