InternalWall¶
Wall or floor between two zones: side a faces the zone of propsBus_a, side b the other
FastSmoothBuildings.Envelope.InternalWall, model (source)
Extends PartialOpaque.
Purpose
Wall or floor between two zones: the conduction of
PartialOpaque with side a facing the
zone of propsBus_a and side b the zone of propsBus_b. The layers are given from
side a; all the layer boundaries T[1] (side a) to T[nLay + 1] (side
b) are states.
Equations
At each face, Q = Qrad − Qint: the radiation the zone of that side
gives to the face minus the convection to its air
(interiorConvection).
azi and til are those of side a; side b faces the other way, its natural
convection coefficients are taken at the tilt π − til, and it is the floor of its zone when
side a is a ceiling (til = 0).
Parameters
epsLw,absSol: the long-wave emissivity and the solar absorptance of both faces, 0.84 by default as Buildings'surBou; the emissivities and absorptances of the construction record are not used.
Use
The partition of Examples.TwoZones.
Parameters¶
| Parameter | Type | Unit | Default | Description |
|---|---|---|---|---|
| epsLw | Real | 0.84 | Long-wave emissivity of both faces (Buildings surBou) | |
| absSol | Real | 0.84 | Solar absorptance of both faces (Buildings surBou) |
Revisions¶
- October 2026: moved from trano's
FastModel.Envelope.